Description
Accuracy/Performance*
Repeatability
Capable of 0.02% or better at any flow rate over entire range
Linearity
Over 5:1 range
Mech. registration: capable of ± 0.125% or better from max. nom. flow rate
Elect. registration: capable of ±0.10% or better from max. nom. flow rate
Over 10:1 range
Mech. registration: capable of ±0.22% or better from max. nom. flow rate
Elect. registration: capable of ± 0.10% or better from max. nom. flow rate
Over 40:1 range
Mech. registration: capable of ±0.5% or better from max. nom. flow rate
Elect. registration: capable of ±0.15% or better from max. nom. flow rate
Temperature range
-40° F to 160° F (-40° C to 71° C)
*Stated accuracy obtainable when all variables remain constant. Reading/measurements
reflect a minimum of one minute of flow at selected rate(s). All accuracy statements
based on metering safety solvent (aliphatic hydrocarbon), approximate viscosity 1 CPS.
On higher viscosity products, the average deviation in accuracy will be less.